Honeywell 900TCK

Product Introduction This is a dedicated accessory cable kit for Honeywell ControlEdge HC900 I/O modules. It connects HC900 I/O module terminal interface to external field terminal block or remote junction box. It includes shielded multi-core cable, pre-terminated connectors, cable ties and installation accessories. It simplifies field wiring work and reduces wiring error risk for HC900 I/O system.

Category:

Description

Honeywell 900TCK

Technical Specifications

  • Cable Type: Twisted pair shielded multi-core industrial cable
  • Rated Voltage: 300 V
  • Cable Conductor: 22 AWG tinned copper wire
  • Insulation Material: Cross-linked polyolefin
  • Shielding: Overall braided copper shield
  • Operating Temperature Range: -20°C to +75°C
  • Bend Radius: Minimum 8 times cable outer diameter
  • Connector: Pre-crimped matching connector for HC900 I/O module
  • Cable Length: Custom standard length options
  • Certification: UL, CE, RoHS

Functional Features Full copper braided shielding reduces electromagnetic interference from motor and frequency converter. Pre-terminated connectors eliminate on-site crimping work. Each core wire has unique color marking for easy identification. It supports quick disconnection for module maintenance. It supports single point shield grounding at cabinet side. It matches all HC900 digital and analog I/O modules. It provides mechanical strain relief at connector end.

Application Scenarios HC900 I/O module remote terminal wiring Control cabinet internal I/O signal wiring Field junction box connection for analog and digital signals HC900 system project new installation On-site wiring renovation and replacement HC900 spare accessory stock

Performance Parameters

  • Conductor DC Resistance: less than 60 Ω per kilometer
  • Shield Coverage Ratio: greater than 85%
  • Insulation Resistance: greater than 1000 MΩ per kilometer
  • Signal Attenuation: less than 0.5% at 100m length
  • Cable Flame Rating: VW-1 flame retardant

Material Composition Tinned copper conductor Cross-linked polyolefin insulation Polyester separator Braided copper shield layer PVC outer jacket Nylon strain relief component Nylon cable tie Metal locking connector shell

Structural Features Multi-core twisted pair structure for signal crosstalk suppression. One end pre-assembled with dedicated locking connector for HC900 I/O module. The other end is loose wire or terminal connector according to variant. Strain relief design at connector root prevents cable breakage during pulling. Color coded core wire for each signal channel. Outer jacket is abrasion resistant and oil resistant.

Working Principle The cable transmits analog and digital signals between I/O module and field terminal block. The braided shield layer conducts induced electromagnetic noise to single point ground in control cabinet. Twisted pair structure reduces differential mode interference for low level analog signal. The pre-terminated connector ensures reliable electrical contact between module and cable.

Installation Requirements Route cable separately from high voltage power cable and variable frequency drive cable. Connect shield ground only at cabinet side, field side shield must be floating. Keep cable bend radius larger than minimum requirement. Do not pull cable directly by connector body. Fix cable with cable tie to avoid vibration stress on connector.

Usage Notes Do not cut or modify the pre-terminated connector end. Do not use the cable for power transmission circuit. Avoid dragging cable over sharp metal edge to prevent jacket damage. Do not expose cable to strong solvent and corrosive liquid. Replace cable immediately when jacket crack or core wire damage is found.