Description
Emerson 248HANAA2XA
Technical Specifications:
- Brand: Emerson (Rosemount)
- Model: 248HANAA2XA
- Product Type: Temperature Transmitter
- Form Factor: DIN B
- Input Types: 2, 3, and 4-wire RTD, thermocouple, millivolt, ohm
- Output: 2-wire 4-20mA with HART protocol
- Power Supply: 12-42.2VDC (HART protocol), 9-32VDC (Foundation Fieldbus)
- Digital Accuracy: 0.20°C (0.36°F) or 0.1% of span
- Stability: 0.1% of reading or 0.1°C (0.18°F) per year
- Ambient Temperature Effect: ±0.006°C per 1.0°C change
- Operating Temperature: -50°C to +85°C
- Storage Temperature: -50°C to +120°C
- Humidity: 0-95% non-condensing
- Electrical Isolation: 2.5kVAC input/output
- Protection Rating: IP66/IP68 (depending on housing)
- Certifications: IEC 61508 SIL2, ATEX, IECEx, Ex d/ia IIC T6, ABS, BV, DNV, LR
- Communication: HART 5/7
- Origin: United States
Functional Features:
- Multi-Sensor Compatibility: Supports 2/3/4-wire RTD, thermocouple, potentiometer, linear resistor, and millivolt inputs
- High Measurement Accuracy: 0.20°C digital accuracy for precise temperature monitoring
- Excellent Stability: 0.1% reading or 0.1°C per year stability reduces calibration frequency
- HART Communication: Enables remote configuration, diagnostics, and data reading
- Fault-Safe Operation: NAMUR NE43 compliant fault indication (21-23mA for high fault, ≤3.6mA for low fault)
- Automatic Calibration: Internal self-calibration with each temperature update eliminates long-term drift
- Environmental Compensation: Built-in ambient temperature and cold junction compensation
- Sensor Diagnostics: Real-time monitoring for open circuit, short circuit, and out-of-range conditions
- Wide Power Range: 12-42.2VDC operation compatible with most industrial power systems
- Global Certifications: Multiple explosion-proof and marine certifications for hazardous area use
Application Scenarios:
- Temperature monitoring in power generation boiler and turbine systems
- Reactor and distillation column temperature control in petrochemical plants
- Storage tank temperature monitoring in oil and gas facilities
- Fermentation tank and sterilizer temperature control in food and pharmaceutical industries
- Transformer and generator winding temperature monitoring
- Pipeline medium temperature measurement in process industries
- HVAC system temperature monitoring
- Marine and offshore platform temperature monitoring systems
Performance Parameters:
- Accuracy: 0.20°C (0.36°F) or 0.1% of span
- Stability: 0.1% of reading or 0.1°C per year
- Response Time: Fast digital processing with configurable damping
- Isolation: 2.5kVAC input/output isolation
- EMC Performance: Compliant with EN61326 and NAMUR NE21 standards
- Diagnostic Coverage: NAMUR NE107 compliant self-monitoring
Material Composition:
- Industrial-grade electronic circuit board
- Precision analog-to-digital converter
- Microprocessor for signal processing
- HART communication module
- Input protection and isolation circuits
- Aluminum, stainless steel, or polypropylene housing options
- High-quality terminal blocks and connectors
- Environmental sealing gaskets
Structural Features:
- DIN B form factor for head-mount installation
- Compact design for space-constrained applications
- Front-accessible terminal blocks for sensor wiring
- LED indicators for status indication
- Local configuration interface
- Robust housing with IP66/IP68 protection
- DIN rail mounting option available
- Sanitary connection options for food and pharmaceutical use
Working Principle:
The 248HANAA2XA receives temperature signals from field sensors (RTD, thermocouple, or millivolt sources) through its input terminals. The analog signal is amplified, filtered, and linearized through precision conditioning circuits. A high-resolution ADC converts the analog signal to digital values, which are processed by the internal microprocessor. The processor applies sensor-specific calibration constants, ambient temperature compensation, and cold junction compensation (for thermocouples) to ensure measurement accuracy. The processed temperature value is then converted to a proportional 4-20mA analog output signal, with HART digital communication superimposed on the analog signal. The transmitter continuously performs self-diagnostics, monitoring sensor integrity, internal circuitry, and communication status.