Description
Emerson KJ3002X1-BC1 12P0681X092 Analog Input Module
Technical Specifications
- Brand: Emerson
- Product Line: DeltaV
- Module Type: Analog input module with HART support
- Part Number: KJ3002X1-BC1 12P0681X092
- Number of Channels: 8 independent analog input channels
- Signal Input Range: 4-20 mA
- HART Support: Yes; supports HART communication over the 4-20 mA loop
- RTD Input Support: Supported in applicable configurations
- Local Bus Power: 12 V DC at 150 mA
- Bussed Field Power: 24 V DC at 300 mA
- Field Circuit Rating: 24 V DC at 32 mA
- Power Consumption: Typically not more than 15 W under normal operation
- Ambient Temperature: 0 to 60°C
- Relative Humidity: 5% to 95%, non-condensing
- Shock Rating: 10 g, half sine wave for 11 ms
- Vibration Rating: 1 mm peak-to-peak from 5 to 16 Hz; 0.5 g from 16 to 150 Hz
- Airborne Contaminants: ISA-S71.04-1985 Class G3
- Protection Rating: IP20
- Terminal Block Key Position: A1
Functional Features
- Eight Analog Inputs: Allows simultaneous acquisition of eight 4-20 mA signals.
- HART Pass-Through: Enables digital communication with HART-enabled field devices.
- Field Device Power Supply: Provides 24 V DC field power to support two-wire transmitters.
- Channel Diagnostics: Monitors channel health, wiring integrity, and module status.
- Low Power Consumption: Typically under 15 W, reducing heat generation inside the cabinet.
- Rotary Keying System: Ensures correct matching between the I/O card and terminal block.
- Hot-Swap Under Conditions: May be removed or inserted with system power energized only when supported safety conditions are met.
Application Scenarios
- Process pressure, temperature, level, and flow measurement
- HART smart transmitter integration
- DCS analog signal acquisition
- Chemical, oil and gas, and power plant instrumentation
- Water and wastewater process monitoring
- Pharmaceutical and food process control loops
Performance Parameters
- Channels: 8 analog inputs
- Input Signal: 4-20 mA
- HART Communication: Supported
- RTD Compatibility: Supported where configured
- Field Power Output: 24 V DC at 300 mA bussed field power
- Field Circuit Current: 24 V DC at 32 mA
- Module Power Draw: Up to approximately 15 W
- Operating Temperature: 0 to 60°C
- Protection Class: IP20
Material Composition
- Module Body: Industrial-grade PCB and housing materials
- Connectors: DeltaV carrier backplane connector and field terminal block
- Internal Circuitry: Analog input conditioning, HART communication circuitry, and isolation components
- Protection Elements: Input protection, fuse elements, and diagnostic circuits
- Keying Components: Rotary keying system for terminal block compatibility
Structural Features
- DeltaV Plug-In Form Factor: Installs directly into a DeltaV carrier.
- Eight-Channel Density: Provides high channel count in a compact module.
- Terminal Block Keying: Prevents incorrect wiring configuration after installation.
- Front or Side Status Indication: Provides module and channel status visibility.
- Backplane Integration: Communicates with the DeltaV controller through the carrier backplane.
Working Principle
Field transmitters send 4-20 mA signals to the KJ3002X1-BC1 analog input channels. The module conditions each current signal, converts it into a digital value, and transfers the data to the DeltaV controller through the backplane. HART digital signals superimposed on the 4-20 mA loop are passed through to support device configuration, diagnostics, and status monitoring. The module can also supply 24 V DC power to field devices, simplifying wiring for two-wire instruments.
Installation Requirements
- Install the module only in a compatible DeltaV carrier.
- Set the terminal block key position to A1 before connecting field wiring.
- Verify that field power and local bus power requirements are satisfied.
- Use shielded instrument cable for 4-20 mA and HART signals.
- Separate instrument wiring from power cables to reduce electrical noise.
- Confirm that the field loop voltage is sufficient for the connected transmitter and HART communication.
- After installation, verify channel status through DeltaV diagnostics or AMS Device Manager.