Emerson MFM600N0P1

Product Introduction MFM600N0P1 is an analog input module for the Emerson Daniel flow computer range. The module receives differential pressure, pressure, temperature, and frequency flow measurement signals and uploads them over Modbus or a dedicated bus to the flow computer for natural gas and oil/gas custody transfer. It is a card in the Daniel flow computer chassis for long-distance oil/gas pipelines and custody metering.

Category:

Description

Emerson MFM600N0P1

Technical Specifications

  • Product type: Flow computer analog input module
  • Inputs: Multi-channel 4 to 20 mA, RTD, frequency
  • Accuracy: 0.1 % FS
  • Sampling: 16-bit ADC
  • Supply: Chassis internal DC24V
  • Isolation: Channel isolated from chassis
  • Temperature: -40 °C to +70 °C
  • Storage: -55 °C to +85 °C
  • Humidity: 5 % to 95 %, non-condensing
  • Protection: IP20
  • Installation: Card-in-chassis
  • Communication: Modbus RTU

Functional Features

  • DP, pressure, temperature signal acquisition
  • Frequency input for turbine meter pulses
  • 0.1 % high-precision
  • Channel isolation and wire-break diagnosis
  • Modbus upload to flow computer
  • Front panel LEDs per channel
  • Wide-temperature -40 °C to +70 °C
  • Custody-metering accuracy
  • Industrial-grade components
  • Field station environment

Application Scenarios

  • Natural gas custody transfer flow computer
  • Oil/gas long-distance pipeline DP meter
  • Oilfield separator flow measurement
  • Refinery oil/gas metering
  • Daniel flow computer system I/O

Materials and Construction

  • Front panel: Metal panel
  • PCB: FR4 board
  • Core: 16-bit ADC, signal conditioning
  • Connector: Chassis dedicated board connector
  • Terminals: Screw-fastened terminals
  • Passive components: Precision resistors, TVS

Structural Features

  • Card structure in Daniel flow computer chassis slot
  • Front panel LEDs and field terminals
  • Analog and frequency input partitions
  • Card locking
  • Metal panel shielding
  • Fanless cooling

Working Principle Field DP, pressure transmitter 4 to 20 mA and RTD temperature signals enter terminals; conditioning after 16-bit ADC sampling. Frequency channels count turbine meter pulses. Data is uploaded over Modbus to the flow computer, which computes volumetric and energy flow per natural gas formulas. LEDs indicate channel status.

Installation Requirements

  • Insert chassis slot with power off
  • Shielded twisted pair signal wires
  • Three-wire RTD compensation
  • Chassis grounding
  • Temperature -40 °C to +70 °C
  • Configure channels in flow computer software after power-up
  • Custody metering requires periodic calibration

Precautions

  • Do not hot-swap online
  • Custody metering calibrated per regulations
  • Sensor accuracy matches module
  • Store spares in anti-static moisture-proof packaging
  • Configure channels after replacement
  • Periodically calibrate zero