Vibro-Meter MPC4 200-510-076-114

Product Introduction MPC4 200-510-076-114 is a cabinet power supply for the Vibro-Meter MMS6000 vibration monitoring family. The unit converts external AC to MMS6000 rack DC working voltages with redundant parallel operation and fault monitoring. Rack-mounted in vibration monitoring cabinets for steam turbines, gas turbines, and compressors.

Category:

Description

Vibro-Meter MPC4 200-510-076-114

Technical Specifications

  • Product type: Vibration monitoring cabinet power
  • Input: AC115/230 V
  • Output: DC24 V, DC±15 V, DC5 V
  • Redundancy: Dual power parallel
  • Isolation: Input/output isolated
  • Temperature: -10 °C to +55 °C
  • Storage: -40 °C to +85 °C
  • Humidity: 5 % to 95 %, non-condensing
  • Protection: IP20
  • Installation: Cabinet rail / panel
  • Fault output: Relay contacts

Functional Features

  • Multi-rail DC supply to MMS6000 rack
  • Dual redundant parallel
  • Input overvoltage, undervoltage, overcurrent, short-circuit protection
  • Fault relay contact output
  • Front panel LEDs
  • Input/output isolation
  • Industrial-grade components
  • Continuous operation
  • Cabinet centralized supply
  • Plant environment

Application Scenarios

  • MMS6000 monitoring cabinet supply
  • Steam turbine TSI system power
  • Plant turbine monitoring cabinet supply
  • Petrochemical unit monitoring cabinet power
  • Rotating machinery protection system supply

Materials and Construction

  • Housing: Metal
  • PCB: FR4 board
  • Power: Switching modules, capacitors
  • Relay: Fault relay
  • Terminals: Screw-fastened
  • Heat: Metal heat sink

Structural Features

  • Metal housing rail/panel mount
  • Front panel LEDs
  • Side AC input and DC output terminals
  • Internal EMI filter, conversion, output partitions
  • Natural convection heat sink
  • Terminal strip

Working Principle AC input after EMI filtering and rectification feeds a switching converter; high-frequency isolation steps down and rectifies to DC24 V, ±15 V, 5 V output to the monitoring rack. Dual supplies current-share. Monitoring detects voltage and current; abnormalities trigger LEDs and relay.

Installation Requirements

  • Rail or panel mount
  • AC input by voltage class
  • DC output to rack per drawing
  • Cabinet grounding
  • Temperature -10 °C to +55 °C
  • Verify output voltages after power-up
  • Dual supplies on independent AC loops

Precautions

  • Confirm redundancy before online replacement
  • AC input voltage must not be wrong
  • DC output polarity correct
  • Store spares in moisture-proof packaging
  • Periodically check output voltage
  • Confirm rack voltage after replacement