Woodward PEAK200-HVAC 8200-1501

Product Introduction: Woodward PEAK200-HVAC 8200-1501 is an intelligent HVAC dedicated control module for industrial power plant and factory central air-conditioning and ventilation systems. It realizes automatic temperature adjustment, fan linkage control, wind pressure monitoring and equipment energy-saving operation management of industrial HVAC systems. It adapts to the constant temperature and ventilation control requirements of industrial control rooms and equipment rooms.

Category:

Description

Woodward PEAK200-HVAC 8200-1501

Technical Specifications: Working power supply: 24 VDC / 110 VAC optional Temperature signal acquisition channel Fan start-stop and frequency conversion control output Operating temperature: -20 ℃ to +60 ℃ Communication: Modbus remote monitoring Protection grade: IP20

Functional Features: Intelligent temperature real-time monitoring and automatic adjustment Ventilation fan linkage start-stop control HVAC system fault self-diagnosis Remote data viewing and parameter adjustment Energy-saving operation mode automatic switching

Application Scenarios: Power plant control room central air conditioning system Industrial factory equipment room ventilation control system Automation cabinet constant temperature and humidity control equipment Large industrial building HVAC intelligent control terminal

Performance Parameters: High-precision temperature collection accuracy Stable long-term equipment linkage control Low power consumption energy-saving operation

Material Composition: Industrial control PCB board Temperature sampling chip Relay drive output components Flame-retardant plastic shell

Structural Features: DIN rail compact installation structure Integrated wiring terminal and indicator lights Built-in independent signal processing circuit

Working Principle: The module collects real-time indoor temperature and wind pressure signals, compares with the set temperature threshold, automatically controls the start-stop and speed adjustment of HVAC fans and air conditioning equipment, and realizes automatic constant temperature and ventilation of the equipment room.

Installation Requirements: Installed in HVAC control cabinet Temperature sensors are installed in ventilation stable area Standard shielded signal wiring Reliable equipment grounding

Precautions for Use: Avoid installation in high-temperature and humid areas Regularly calibrate temperature sampling accuracy Prohibit overload output operation