Description
Bently 3500/15-05-05-GCN
Technical Specifications
- Module Type: Dual Universal AC Power Supply (Enhanced CN)
- Upper Slot Input: Universal AC Voltage (85 to 264 Vac RMS)
- Lower Slot Input: Universal AC Voltage (85 to 264 Vac RMS)
- Input Frequency: 47 to 63 Hz
- Regional Compliance: Enhanced GCN Standard Certification
Functional Features
- Enhanced Regional Compliance: Meets the latest domestic regulatory, safety, and electromagnetic compatibility (EMC) requirements for the Chinese market.
- Seamless Redundancy: Guarantees zero-interruption power transfer between the lower primary and upper secondary supplies.
- Advanced Line Filtering: Standard line noise filters provide superior immunity against electrical transients and grid fluctuations common in heavy industrial environments.
- Continuous Diagnostics: Actively monitors internal health and communicates power status to the Transient Data Interface (TDI) module.
Application Scenarios
Ideal for critical infrastructure projects, new-build power plants, and high-end petrochemical facilities in China that require the most current domestic safety and compliance certifications for automated machinery protection.
Performance Parameters
- Operating Temperature Range: -30°C to +65°C (-22°F to +150°F)
- Storage Temperature Range: -40°C to +85°C (-40°F to +185°F)
- Humidity Tolerance: 95% non-condensing
- Power Conversion Efficiency: High-efficiency design minimizing thermal output
Material Composition
Constructed with high-grade, flame-retardant materials, robust EMI shielding, and premium electronic components selected to meet stringent enhanced regional safety standards.
Structural Characteristics
Identical physical form factor to the standard 3500/15 dual power supply, occupying the leftmost upper and lower half-height slots. Features distinct “GCN” compliance markings on the front panel and rear identification labels.
Working Principle
Operates on the same dual-redundant switch-mode power conversion principle as the standard 3500/15, but with optimized firmware and hardware filtering tuned to meet the specific electrical grid characteristics and safety standards denoted by the GCN suffix.
Installation Requirements
Install strictly in the designated leftmost power slots of the 3500 rack. Ensure proper single-point grounding to prevent ground loops. Verify that the enhanced GCN certification aligns with the specific hazardous area or safety classification of the installation site.
Usage Precautions
Do not mix GCN-certified power supplies with non-certified legacy modules in a redundant pair, as this may void the enhanced compliance certification. Always verify the “Power OK” LED is illuminated after installation.