Description
Bently 991‑10‑70‑01‑00
Technical Specifications:
- Matching Transducer‑System: 3300 NSv probe plus extension‑cable, total electrical‑length 7 meters
- Full‑Scale Measuring‑Range: ‑0.25 mm ~ +0.25 mm axial thrust displacement
- Power‑Supply Mode: Two‑wire loop‑powered, +12 VDC ~ +35 VDC
- Output Signal: 4‑20 mADC two‑wire loop
- Loop‑Accuracy: ±1.5% full‑scale
- Nominal Sensitivity: 7.87 V/mm
- Frequency‑Response: 0 Hz ~ 10 kHz
- Diagnostic Terminal: Prox‑Out gap‑voltage output terminal available
- Maximum Allowable Loop‑Resistance: 1000 Ω @35 VDC
- Mounting Method: 35 mm DIN‑rail clip‑mount or panel screw‑mount installation
- Operating Temperature: ‑40 °C ~ +85 °C
- Relative Humidity: 0‑95% RH non‑condensing
- Startup‑Inhibition Function: Output maintains NOT‑OK fault‑status within 2‑3 seconds after power‑on Functional Features:
- Integrates complete proximitor‑signal‑conditioning‑circuit; NSv proximity‑probe system directly connects transmitter input terminals without external proximitor‑hardware.
- Two‑wire loop‑power architecture, single‑pair cable accomplishes power‑supply feeding and thrust‑position‑signal transmission, reduces field‑instrument‑wiring‑workload.
- Accessible zero‑point and span potentiometers support convenient on‑site field‑calibration‑adjustment.
- Dedicated test‑input pin enables loop‑function verification without physical NSv‑sensor‑hardware‑connection.
- Built‑in sensor‑loop fault‑detection function; upon probe open‑circuit, short‑circuit fault‑event, output locks to defined NOT‑OK fault‑current‑level to prevent control‑‑system receiving false axial‑thrust‑position‑readings.