Bently Nevada 330130-085-12-05

Product Overview The Bently Nevada 330130-085-12-05 is an 8.5-meter FluidLoc extension cable with connector protectors and multiple agency approvals. Designed for the 3300 XL 8 mm Proximity Transducer System, this cable prevents fluid leakage while providing certified safe operation in hazardous environments.

Category:

Description

Bently Nevada 330130-085-12-05

Technical Specifications

  • Model: 330130-085-12-05
  • Series: 3300 XL Proximity Transducer System
  • Cable Length: 8.5 meters (27.9 feet)
  • Connector Protector and Cable Option: 12 — FluidLoc cable with connector protector
  • Agency Approval: 05 — Multiple approvals (CSA, ATEX, IECEx)
  • Cable Construction: 75 Ω triaxial, Fluorinated Ethylene Propylene (FEP) insulated
  • Capacitance: 69.9 pF/m (21.3 pF/ft) typical
  • Operating Temperature: -51°C to +177°C (-60°F to +350°F)
  • Weight: 0.35 kg
  • Connector Type: Gold-plated ClickLoc miniature coaxial connectors

Function Features

  • FluidLoc technology prevents oil and liquid migration
  • Connector protectors enhance environmental sealing
  • Multiple hazardous area certifications
  • Gold-plated ClickLoc connectors resist corrosion
  • Complete interchangeability with 3300 XL components
  • Backward compatibility with non-XL series

Application Scenarios

  • Turbine supervisory instrumentation in hazardous areas
  • Pipeline compression with oil-saturated environments
  • Power generation equipment requiring fluid sealing
  • Chemical processing with explosive atmospheres
  • Hydroelectric facilities with bearing oil mist

Performance Parameters

  • Extension cable capacitance is 69.9 pF/m typical
  • Impedance is 75 Ω maintained over full length
  • Signal attenuation is minimal
  • Temperature stability across full operating range
  • Calibration compatibility with 3300 XL system

Material Composition

  • Cable jacket is Fluorinated Ethylene Propylene (FEP)
  • FluidLoc sealant prevents liquid ingress
  • Conductors are copper with controlled impedance
  • Connectors are gold-plated brass or beryllium copper

Structural Characteristics

  • FluidLoc cable with connector protector
  • Triaxial shielded design
  • ClickLoc gold-plated connectors
  • Sealed construction for wet environments
  • Flexible for industrial installation

Installation Requirements

  • Match total cable length to Proximitor sensor calibration
  • Maintain minimum 25.4 mm bend radius
  • Route through dedicated conduit when possible
  • Ensure connector protectors are properly seated
  • Verify ClickLoc connection engagement

Operating Considerations

  • Suitable for hazardous areas with multiple certifications
  • FluidLoc effective against synthetic lubricants and oils
  • Inspect seal integrity during preventive maintenance
  • Replace if fluid migration is detected
  • Keep connectors clean before mating