Description
Bently Nevada 3500/33 149986-01
Technical Specifications:
- Module Type: Full-height, 16-channel relay control module (main PWA)
- Power Consumption: Approximately 5.0 watts typical
- Operating Temperature: -30°C to +65°C (-22°F to +150°F)
- Storage Temperature: -40°C to +85°C (-40°F to +185°F)
- Humidity: 95% non-condensing
- Agency Approval Options: CSA/NRTL/C available (part number suffix “-01”) or no approval (“-00”)
Functional Features:
- Controls 16 independently programmable relay outputs via the companion output module
- Each relay contains “Alarm Drive Logic” programmable using AND and OR logic
- Alarm inputs include Alert and Danger states, Not-OK status, or individual PPL from any monitor channel
- Supports complex voting logic for critical machinery protection
- Front panel LEDs indicate module OK status and TX/RX communication
- Requires 3500 Rack Configuration Software version 3.3 or higher
- Requires 3500/22 Transient Data Interface module with firmware version 3.3 or higher
- Requires 3500 Data Acquisition Software version 2.40 or higher
- Requires 3500 Data Display Software version 1.40 or higher
- Not compatible with the 3500/93 LCD display module
- When used with the 3500/94 VGA display module, hardware version 2.0 or higher is required
Application Scenarios:
- High-density relay output applications requiring more than 4 channels
- Complex voting logic implementations for critical machinery
- Multi-machine monitoring systems with extensive alarm routing
- Power generation, petrochemical, and metallurgical plant protection systems
Performance Parameters:
- Channel count: 16 independent relay channels (via companion output module)
- Relay response time: Less than 10 ms typical
- Logic combinations: Unlimited AND/OR combinations of rack alarm inputs
Material Composition:
- High-reliability electronic components on multi-layer PCB
- Metal module enclosure with conformal coating
- Gold-plated backplane edge connectors
Structural Features:
- Full-height module form factor
- Front panel with OK and TX/RX LED indicators
- Plug-in design compatible with any accessible rack slot to the right of the TDI module
- Requires companion I/O module (149992-01) installed in the rear slot
Working Principle:
The 149986-01 main control module receives alarm status information from all monitor modules in the rack via the backplane bus. It evaluates the programmed AND/OR alarm drive logic for each of the 16 relay channels and sends the appropriate drive signals to the companion relay output module (149992-01), which physically switches the relay contacts.
Installation Requirements:
- Install the main control module (149986-01) in any full-height slot to the right of the TDI module
- Install the companion relay output module (149992-01) in the corresponding rear slot
- Configure relay logic using 3500 Rack Configuration Software version 3.3 or higher
Usage Notes:
- The 149986-01 is the control module only — it requires the companion 149992-01 output module for complete functionality
- The 3500/33 is not compatible with the 3500/93 LCD display module
- For applications requiring fewer relay channels, the 3500/32 4-channel relay module is an alternative