DEIF DLQ144-PC-NB

Product Introduction: DLQ144-PC-NB is DEIF 144×144mm marine analog panel indicator. It is a rugged pointer type instrument for marine and offshore control panels. It accepts voltage, current or pulse input signals and displays measured value via analog pointer. It features high vibration resistance and wide temperature working range for harsh marine power system monitoring.

Category:

Description

DEIF DLQ144-PC-NB

Technical Specifications:

  • Panel Cutout Size: 144 ×144 mm
  • Measurement Accuracy: ±1.5% full scale
  • Input Signal Type: 0-10V DC, 4-20mA or pulse signal
  • Front Protection: IP52 with sealing gasket
  • Operating Temperature: -25°C ~ +60°C
  • Storage Temperature: -40°C ~ +85°C
  • Vibration Standard: IEC 68-2-27 shock test compliant
  • Weight: Approx 630 grams
  • Calibration: Rear potentiometer for range fine adjustment

Function Features:

  • Analog pointer display for continuous parameter indication
  • Rear adjustable potentiometer for full scale calibration
  • High shock and vibration resistance for marine vessel operation
  • Optional front illumination for low light cabin environments
  • Wide signal input compatibility for multiple measurement types
  • Overload transient protection for internal measuring mechanism

Application Scenarios:

  • Marine generator control panels
  • Offshore platform power monitoring cabinets
  • Ship propulsion auxiliary control panels
  • Land-based industrial power control panels with high vibration

Material Composition:

  • Front Frame: Self-extinguishing UL94 V0 flame retardant plastic
  • Housing: Impact resistant reinforced plastic
  • Measuring Mechanism: Permanent magnet moving coil assembly
  • Scale Plate: Anti-corrosion coated metal plate
  • Terminals: Tin plated copper screw terminals

Structural Features:

  • Square panel mounting design following DIN 43700 standard
  • Transparent scratch-proof front window
  • Rear mounting clips for fixed installation
  • Rear terminal block for input signal wiring
  • Internal shock absorption structure for vibration isolation

Working Principle: External analog or pulse signal enters the instrument. Internal circuit converts signal to proportional DC current for moving coil mechanism. Magnetic field generates torque to rotate pointer against restoring spring. Pointer position directly indicates measured value on printed scale. Rear potentiometer adjusts signal gain to calibrate full scale reading.

Installation Requirements:

  • Mount on control panel with standard 144mm cutout
  • Fasten mounting clips symmetrically to avoid casing stress
  • Separate signal wiring from high voltage power cables
  • Avoid installation location with strong magnetic field
  • Maintain gasket integrity to preserve front panel protection rating

Usage Notes:

  • Complete full scale calibration after wiring and power on
  • Do not apply voltage or current exceeding rated input range
  • Prevent salt mist and humidity entering instrument housing
  • Check pointer zero position periodically
  • Disconnect all input signals before removing instrument