Description
Emerson 1P00028G01
Technical Specifications: Rated input power supply: 24 VDC Backplane communication bus rate: Ovation proprietary high-speed bus Operating temperature:0 ℃ ~60 ℃ Storage temperature:-40 ℃ ~85 ℃ Relative humidity:5% ~95% non-condensing
Functional Features: Integrated power distribution bus for all rack modules. High-speed parallel communication bus for data exchange between controller and I/O modules. Gold-plated card connectors reduce contact resistance. Each slot has independent power circuit protection. Slot number marking printed on board surface. Mechanical positioning structure prevents module misinsertion.
Application Scenarios: Ovation DCS control rack assembly for thermal power plant, petrochemical plant main control cabinet, metallurgy process control rack, pulp and paper factory DCS cabinet, water treatment main control rack.
Performance Parameters: Connector contact resistance less than 5 milliohm Vibration resistance:10 Hz~150 Hz,0.5g Shock resistance:10g peak,11ms MTBF:245000 hours
Material Composition: Backplane substrate: FR4 thick epoxy glass fiber board. Connector contact: gold-plated copper alloy. Reinforcement bracket: cold rolled steel with anti-corrosion coating. Insulation spacer: flame retardant plastic.
Structural Features: Horizontal multi-slot board structure fixed inside standard control rack. Multiple module slots arranged along board length. Edge connectors on each slot for plugging Ovation modules. Fixing holes for assembly with rack frame. Built-in shielding layer reduces electromagnetic interference.
Working Principle: External 24V DC power supply connects to backplane power terminal. Backplane distributes stable DC power to every module slot. Controller module and I/O cards plug into corresponding slots and connect to backplane communication bus. All modules exchange real-time process data and control commands through the backplane high-speed bus.
Installation Requirements: Fix backplane firmly inside standard Ovation rack with designated screws. Tighten fixing screw torque to manufacturer specified value. Keep backplane away from high voltage power cables. Inspect connector surface before inserting modules. Cut off rack power before backplane installation or replacement.