HONEYWELL CC-TAIX01

Product Introduction: CC-TAIX01 is temperature analog input module for Honeywell Experion PKS C300 DCS system. It receives temperature signals from RTD resistance temperature detectors and thermocouple sensors. It converts resistance or millivolt temperature signal into digital temperature value and sends data to C300 controller. It supports multiple thermocouple types and RTD types, with built-in cold junction compensation function.

Category:

Description

HONEYWELL CC-TAIX01

Technical Specifications Backplane power supply from C300 rack Multi-channel temperature input interface Support RTD and multiple types of thermocouple Built-in cold junction compensation circuit Per-channel signal isolation Rack plug-in design compatible with C300 I/O rack

Functional Features Acquire temperature signal from field RTD and thermocouple sensors Convert resistance or millivolt signal into accurate temperature engineering value Complete cold junction compensation for thermocouple measurement Electrically isolate field sensor circuit and DCS control circuit Detect sensor open circuit and short circuit fault Upload module hardware fault and sensor wiring fault to Experion operator station

Application Scenarios Chemical, power plant and metallurgy Experion PKS C300 DCS cabinets Reactor, furnace, pipeline temperature measurement High temperature equipment monitoring Continuous production process temperature control

Performance Parameters Operating temperature range 0℃ to 60℃ Relative humidity 5% to 95%, non-condensing High temperature measurement accuracy Stable cold junction compensation performance Comply with industrial EMC standards

Material Composition FR-4 multilayer printed circuit board Gold-plated backplane edge connectors High precision analog conversion chips Cold junction compensation sensing components Signal conditioning and surge protection components Flame retardant anti-static plastic front panel

Structural Features Standard rack plug-in card structure Front panel equipped with LED indicators for power, running and fault status Rear gold fingers connect rack backplane bus Anti-reverse insertion positioning notch Model number printed on card surface Cooperate with matched FTA terminal base for field temperature sensor wiring

Working Principle Millivolt signal from thermocouple or resistance signal from RTD enters module through FTA terminal base. Signal conditioning circuit processes raw temperature signal. Cold junction compensation circuit compensates thermocouple reference junction temperature. Analog-to-digital converter converts signal into digital temperature data and transmits to C300 controller via backplane bus. Diagnostic circuit continuously monitors sensor loop state and reports open or short circuit fault.

Installation Requirements Wear anti-static wrist strap during installation and removal Insert card fully into rack slot and tighten fixing screw Complete temperature sensor wiring on matched FTA terminal base Cabinet protective grounding must be qualified Use dedicated temperature compensation cable for thermocouple wiring Verify hardware version compatibility with C300 controller firmware

Precautions for Use Do not plug or unplug the module under power-on state Select correct sensor type in engineering station before commissioning Do not connect high voltage signal to temperature input channels Keep thermocouple extension cable away from high power cables Check sensor and cable integrity when temperature reading abnormal