Description
Honeywell CP-DYNA-2AIO
Technical Specifications
- Channel Capacity: 16 slots for analog AIO barrier modules
- Signal Type: 4-20mA analog input and analog output
- Rated Voltage: 300V
- Conductor Specification: 22AWG to 14AWG
- Working Temperature: -20°C to +70°C
- Storage Temperature: -40°C to +85°C
- Relative Humidity: 5% to 95% RH non-condensing
- Isolation Rating: Intrinsic safety isolation compliant with IEC 60079
- Mounting Mode: 35mm DIN rail mounting or surface screw mounting
- Certification: ATEX, IECEx, UL, CE
Functional Features It supports hot swap of individual MTL barrier modules without disconnecting backplane wiring. It has independent screw terminal for each channel field side and control side. It provides common power distribution bus for barrier modules. It supports fault status signal transmission from barrier to DCS system. It has marking label for each channel number. It supports daisy chain power supply between multiple backplanes. It provides mechanical locking structure for barrier modules to prevent loose contact under vibration.
Application Scenarios Petrochemical plant hazardous area 4-20mA transmitter signal isolation Refinery explosive zone analog instrument termination Chemical plant solvent tank level and pressure signal isolation Oil and gas offshore platform intrinsic safety signal wiring Pharmaceutical plant solvent production area analog control loop Honeywell DCS intrinsically safe cabinet spare part
Performance Parameters
- Insulation Resistance: greater than 500 MΩ
- Contact Resistance: less than 10 milliohm per terminal
- Vibration Resistance: 10-2000Hz, 1g continuous vibration
- Mean Time Between Failures: 1050000 hours
- Flame Retardant Rating: UL94 V-0
Material Composition FR4 flame retardant PCB base Nylon flame retardant terminal block Tinned copper terminal pins Steel DIN rail elastic clip Polycarbonate channel marking cover Nickel plated copper power bus bar ABS plastic module locking buckle
Structural Features Flat rectangular backplane structure. One side is row of slots for plugging MTL AIO barrier modules. Two rows of screw terminals are arranged on front side, field terminal and control side terminal separated. Built-in power distribution bus runs through all slots. DIN rail clip is installed on back side. Each channel has printed channel number marking. Locking buckle on each slot fixes barrier module.
Working Principle Field intrinsically safe analog signal enters field side terminal of backplane. The signal passes through MTL barrier module inserted on the slot. The barrier limits energy and transfers safe analog signal to control side terminal. Control side terminal connects to Honeywell DCS I/O module. The backplane distributes 24VDC power supply to each barrier module through internal power bus.
Installation Requirements Mount the backplane on 35mm DIN rail or flat cabinet surface with screws. Wire field hazardous side cable to field terminal and control cabinet cable to control side terminal. Insert MTL4544 or MTL4549Y analog barrier into each slot and lock buckle. Connect 24VDC power supply to backplane power terminal. Verify power and signal continuity after wiring. Separate hazardous zone wiring and safe zone wiring strictly.
Usage Notes Only certified intrinsically safe barrier modules can be used on this backplane. Do not mix digital barrier modules on this AIO backplane. Field wiring must comply with ATEX intrinsic safety installation standard. Do not exceed the rated voltage of terminal. Tighten terminal screws to specified torque to avoid heat and poor contact.