Vibro-Meter MPC4 200-510-078-115

Product Introduction MPC4 200-510-078-115 is a cabinet power unit for the Vibro-Meter MMS6000 vibration monitoring family, a different hardware version in the same MPC4 family with minor output capacity and interface differences. The unit supplies multi-rail DC to the MMS6000 rack in redundant parallel operation. Rack-mounted in vibration monitoring cabinets for large rotating machinery protection.

Category:

Description

Vibro-Meter MPC4 200-510-078-115

Technical Specifications

  • Product type: Vibration monitoring cabinet power
  • Input: AC115/230 V
  • Output: DC24 V, DC±15 V, DC5 V
  • Redundancy: Dual power parallel
  • Isolation: Input/output isolated
  • Temperature: -10 °C to +55 °C
  • Storage: -40 °C to +85 °C
  • Humidity: 5 % to 95 %, non-condensing
  • Protection: IP20
  • Installation: Cabinet rail / panel
  • Fault output: Relay contacts

Functional Features

  • Multi-rail DC supply to MMS6000 rack
  • Dual redundant parallel uninterrupted
  • Input overvoltage undervoltage overcurrent short-circuit protection
  • Fault relay output to DCS
  • Front panel LEDs
  • Input/output isolation
  • Industrial wide-temperature
  • Continuous operation
  • Cabinet centralized supply
  • Plant and petrochemical environment

Materials and Construction

  • Housing: Metal
  • PCB: FR4 board
  • Power: Switching modules, filter capacitors
  • Relay: Fault relay
  • Terminals: Screw-fastened
  • Heat: Metal heat sink

Structural Features

  • Metal housing rail/panel mount
  • Front panel LEDs
  • AC input and DC output terminals
  • Internal circuit partitions
  • Natural convection
  • Terminal strip

Working Principle AC input after EMI filtering and rectification feeds switching conversion, high-frequency isolation steps down and rectifies to multi-rail DC to rack. Dual supplies current-share. Monitoring detects voltage and current; abnormalities trigger LEDs and relay.

Installation Requirements

  • Rail or panel mount
  • AC input correct voltage
  • DC output to rack per drawing
  • Cabinet grounding
  • Temperature -10 °C to +55 °C
  • Verify output voltages after power-up
  • Dual supplies independent AC loops

Precautions

  • Confirm redundancy normal before replacement
  • AC voltage must not be wrong
  • DC polarity correct
  • Store spares in moisture-proof packaging
  • Periodically check output voltage
  • Confirm rack supply after replacement