Wartsila PDM-20110V PAEE045083

Product Introduction PDM-20110V PAEE045083 is a protection and control module for Wartsila marine diesel generator monitoring systems. The module collects engine speed, temperature, pressure, and level signals, executes safety protection logic, and outputs alarm and shutdown on limits. It is marine-grade design for main engine and auxiliary genset safety monitoring.

Category:

Description

Wartsila PDM-20110V PAEE045083

Technical Specifications

  • Product type: Diesel engine protection monitoring module
  • Inputs: Temperature PT100, pressure 4 to 20 mA, speed
  • Outputs: Alarm and shutdown relays
  • Supply: DC24 V marine
  • Communication: CAN/RS485
  • Protection: IP56 marine
  • Operating temperature: -25 °C to +70 °C
  • Storage temperature: -40 °C to +85 °C
  • Humidity: 95 % non-condensing
  • Certification: Classification society
  • Installation: Panel/rail
  • Contact rating: AC250 V 5 A

Functional Features

  • Multi-parameter engine monitoring
  • Overspeed, over-temperature, low-pressure shutdown protection
  • Alarm and graded shutdown
  • Marine anti-vibration and humidity
  • Front panel LEDs and display
  • Event logging
  • CAN bus to main controller
  • Sensor wire-break diagnosis
  • Classification society certified
  • Long-term offshore operation

Application Scenarios

  • Marine main engine safety protection
  • Marine genset monitoring
  • Ship auxiliary machinery alarm
  • Offshore platform diesel engines
  • Emergency generator control

Materials and Construction

  • Housing: Anti-corrosion metal
  • Seal: Silicone gasket
  • PCB: FR4 conformal coated
  • Relays: Marine-grade relays
  • Terminals: Marine waterproof terminals
  • Display: LCD/LED

Structural Features

  • Marine sealed housing
  • Front panel display and pushbuttons
  • Rear waterproof cable glands
  • Internal measurement and control
  • Vibration-hardened
  • Anti-corrosion coating

Working Principle PT100, pressure transmitter, and speed sensor signals enter the module. The CPU compares measured values to setpoints. Limits trigger alarm or shutdown relays. Events are logged with timestamps. CAN bus uploads data to the main control display. Sensor wire-break is diagnosed.

Installation Requirements

  • Panel or rail mount
  • Waterproof cable glands tightened
  • Shielded sensor cables
  • DC24 V supply
  • Grounding
  • Temperature -25 °C to +70 °C
  • Set protection values after power-up
  • Classification society acceptance

Precautions

  • Handle sensor wire-break promptly
  • Do not modify protection values arbitrarily
  • Periodically perform function tests
  • Store spares in dry packaging
  • Disconnect power before service
  • Check waterproof cable glands