Description
Honeywell FC-FANWR-24R
Technical Specifications
- Product Type: Redundant rack fan module
- Power Supply: 24 VDC
- Fan Configuration: Dual redundant axial fans
- Speed Feedback: Tachometer speed monitoring for each fan
- Protection Function: Locked rotor protection, overcurrent protection
- Protection Rating: IP20
- Operating Temperature: 0 °C to +60 °C
- Mounting Method: FSC rack slot mounting
Functional Features
- Dual redundant fan design ensures continuous cooling function when single fan fails.
- Independent tachometer sensor monitors rotation speed of each fan.
- Fan fault signal transmits to FSC safety controller for fan failure alarm.
- Brushless DC fan motor reduces operation noise and extends service life.
- Overcurrent and reverse polarity protection protects fan power circuit.
- LED indicators display individual fan running and fault status.
- Quick release structure supports fast replacement without full rack shutdown.
- Low vibration mechanical design adapts to process plant cabinet environment.
- Built-in air filter prevents dust entering rack internal modules.
- Supports continuous airflow to cool FSC CPU and I/O modules.
Application Scenarios
- Honeywell FSC safety instrumented system rack cooling
- Petrochemical plant ESD safety control cabinet thermal management
- Refinery burner management system rack heat dissipation
- Offshore platform FSC safety cabinet cooling
- Chemical plant HIPPS system control rack temperature control
Material Composition
- Module housing: Reinforced plastic frame
- Fan impeller: Fiberglass reinforced plastic blade
- Motor: Brushless DC motor with permanent magnet rotor
- Monitoring PCB: FR4 printed circuit board with speed detection circuit
- Air filter: Dust filter mesh
- Terminal connector: Copper alloy contact pins
Structural Characteristics
- Standard FSC rack slot modular structure.
- Dual axial fans installed side by side inside module frame.
- Front side air filter for dust filtration.
- Rear monitoring PCB collects fan speed signal and outputs fault alarm.
- Quick locking mechanism enables fast module removal and replacement.
- Airflow direction aligns with FSC rack internal thermal path.
Working Principle 24VDC power supplies dual brushless fans. Both fans rotate simultaneously to generate airflow through rack electronic modules. Tachometer sensors detect rotation speed of each fan independently. If one fan stalls or speed drops below threshold, the monitoring circuit triggers fan fault alarm and sends fault signal to FSC controller. The remaining fan continues cooling operation to maintain rack temperature.
Installation Requirements
- Insert FC-FANWR-24R module into designated fan slot of FSC rack.
- Confirm airflow direction matches FSC rack cooling requirement.
- Complete protective earth connection for module frame.
- Verify fault signal wiring to FSC controller.
- Clean air filter before power energization.
- Perform fan operation and fault simulation test after installation.
Usage Notes
- Cut off module power before removing fan module.
- Clean air filter regularly to avoid airflow blockage.
- Check fan noise and vibration during routine inspection.
- Replace module immediately when fan fault alarm is triggered.
- Do not block air inlet and outlet during system operation.
- Keep cabinet free of oil mist and corrosive gas.