METSO A413654

Product Introduction: This universal analog input module belongs to Metso DNA DCS system. It supports multiple types of analog signals including 4-20mA current, 0-10V voltage and multiple thermocouple signals. It converts field analog measurement signal into digital signal and uploads to DCS controller. It is suitable for mixed measurement of pressure, flow and temperature.

Category:

Description

METSO A413654

Technical Specifications: 8-channel universal analog input; support 4-20mA, 0-10V, J, K, T, E type thermocouple; 16-bit ADC conversion; built-in cold junction compensation; channel electrical isolation; backplane 24VDC power supply; rack plug-in installation; operating temperature range 0℃ to +55℃; each channel LED indicator; protection class IP20.

Functional Features: Multi-type signal input, software configurable per channel; built-in automatic cold junction compensation for thermocouple; hardware open circuit detection; single-channel fault isolation; module full self-diagnosis; upload measurement data and fault alarm to DCS monitoring system.

Application Scenarios: Mixed signal collection cabinet of boiler auxiliary system in thermal power plant; multi-parameter collection cabinet in chemical continuous production device; mixed pressure and temperature signal cabinet in pulp and paper factory; comprehensive process signal collection cabinet in water treatment plant.

Performance Parameters: Measurement accuracy ±0.15% full scale; low zero drift; stable signal transmission under long-distance wiring; meet industrial EMC anti-interference standards; support 7×24 hours uninterrupted continuous operation.

Material Composition: Glass fiber epoxy multilayer PCB circuit board; high-precision ADC chip; photoelectric isolation components; gold-plated edge connector; metal front panel; circuit board coated with three-proof protective coating.

Structural Features: Rack plug-in modular structure; front panel equipped with LED indicators for power, running and channel fault status; rear gold-plated edge connector connects to DCS rack backplane bus; analog signal circuit and system logic circuit are physically separated; panel fitted with mechanical locking buckle.

Working Principle: Field transmitters and thermocouple signals are sent to A413654 module through supporting terminal base. Thermocouple signal is compensated by built-in cold junction circuit. ADC chip converts analog signal into digital value. Digital data is uploaded to DCS controller through backplane bus. The module detects loop break, over-range fault and uploads alarm information.

Installation Requirements: Install in designated slot of Metso DNA I/O rack and match with original terminal base. Use twisted shielded cable for analog signal wiring. Shield layer adopts single-point grounding. Signal cables and power cables are laid in separate trunking. Cabinet protective grounding terminal must be connected reliably.

Precautions for Use: Confirm signal type and wiring polarity before power on. Cut off field loop power before wiring. Do not access high voltage signal to analog input channel. Cut off backplane power before module disassembly. Check terminal tightness regularly. Prevent cabinet internal condensation.