Description
NI PCI-6110
Technical Specifications
- Brand: National Instruments
- Product Family: S Series Multifunction DAQ
- Model: PCI-6110
- Bus Interface: PCI
- Analog Input Channels: 4 pseudodifferential
- Analog Input Resolution: 12-bit
- Maximum Analog Input Sampling Rate: 5 MS/s
- Minimum Analog Input Sampling Rate: 1 kS/s
- ADC Type: Pipeline ADC
- Input Coupling: DC or AC
- Overvoltage Protection: ±42 V on analog input channels
- Analog Output Channels: 2 voltage outputs
- Analog Output Resolution: 16-bit
- Maximum Analog Output Update Rate: Up to 4 MS/s single-channel, up to 2.5 MS/s dual-channel, system dependent
- Digital I/O Lines: 8 TTL/CMOS-compatible lines
- Counters/Timers: General-purpose counter/timer resources
- FIFO Buffer: 8,192 samples for analog input
- I/O Connector: 68-pin SCSI-II type
- Power Requirement: +5 V DC, up to 2.5 A for PCI-6110
- Driver Software: NI-DAQmx or compatible NI driver
Functional Features
- High-speed sampling: Supports up to 5 MS/s analog input acquisition.
- AC/DC coupling: Allows flexible signal conditioning for different measurement tasks.
- High overvoltage protection: Provides ±42 V protection on analog inputs.
- Advanced triggering: Supports digital and analog triggering through PFI and RTSI resources.
- High-resolution analog output: 16-bit DAC supports waveform generation and control references.
- Programmable digital I/O: Eight configurable lines for status monitoring and control.
- Counter/timer functions: Supports frequency measurement, pulse counting, and timing operations.
- RTSI bus support: Enables timing and trigger synchronization with other NI devices.
Application Scenarios
- High-speed transient signal capture
- Dynamic voltage measurement
- Power electronics testing
- Pulse and waveform analysis
- Motor drive and inverter testing
- Ultrasonic or acoustic signal acquisition
- Laboratory research requiring fast sampling
- Industrial test systems needing precise trigger synchronization
Performance Parameters
- AI Sampling Rate: Up to 5 MS/s
- AI Resolution: 12-bit
- AI Channels: 4 pseudodifferential
- AO Resolution: 16-bit
- AO Update Rate: Up to 4 MS/s single-channel
- Input Overvoltage Protection: ±42 V
- Input Coupling: AC or DC selectable
- DIO Lines: 8 TTL/CMOS-compatible
- Counter Resolution: General-purpose counter/timer available
Material Composition
- PCB Assembly: High-speed ADC, DAC, digital logic, and timing circuits
- Analog Front End: Input amplifiers, coupling networks, and protection circuitry
- Digital Section: TTL/CMOS I/O buffers and counter logic
- Connectors: 68-pin SCSI-II I/O connector and PCI edge connector
- Shielding: Metal bracket and board-level shielding for noise suppression
Structural Features
- Standard PCI card format: Installs into a compatible PCI slot.
- 68-pin SCSI-II connector: Provides analog, digital, counter, and trigger signals.
- RTSI connector support: Allows multi-device synchronization.
- No manual jumpers: Configuration is performed through software.
- Robust industrial design: Suitable for laboratory and industrial test environments.
Working Principle
The PCI-6110 samples analog input signals using a 12-bit pipeline ADC. Selected channels are converted at high speed and stored in an on-board FIFO before being transferred to the host computer through the PCI bus. The analog output section generates voltage waveforms from digital values using a 16-bit DAC. Digital I/O lines read or drive TTL/CMOS signals, while counter/timer resources measure frequency, period, or pulse events. Triggering can be sourced from internal timers, external PFI lines, or the RTSI bus to synchronize acquisition with other instruments.
Installation Requirements
- Install the card into a compatible PCI slot.
- Verify that the host power supply can provide up to 2.5 A at +5 V for the PCI-6110.
- Connect analog signals using shielded cables and proper grounding.
- Observe the maximum working voltage and overvoltage protection limits.
- Configure input coupling, range, and sampling rate in NI software.
- Use RTSI or PFI connections only when multi-device synchronization is required.
- Install the correct NI driver before commissioning.
Precautions for Use
- Do not exceed the ±42 V overvoltage protection limit.
- Verify input coupling and range settings before applying signals.
- The 12-bit resolution is lower than 16-bit M Series or X Series devices.
- High-speed sampling generates large data volumes; ensure sufficient host memory and bus bandwidth.
- Avoid shorting analog output channels to high-voltage sources.
- Confirm exact channel count, accuracy, and environmental ratings from the official PCI-6110 user manual.